N100

Features

        High Starting Torque - Powerful Operation

        Open Network Communication to Upper Controller

        Versatile Functions

        High Torque Multi-motor Operation

        Conformity to Global Standards

Specifications

200V Class

Item(N100) 004 SF 007 SF 015 SF 004 LF 007 LF 015 LF 022 LF 037 LF
Output Applicable Motor Capacity(kW) 0.4 0.75 1.5 0.4 0.75 1.5 2.2 3.7
Rated Output
Current (A)
3 5 7 3 5 7 11 17
Rated Output
Capacity (kVA)
1.1 1.9 3 1.1 1.9 3 4.2 6.1
Rated Output
Voltage (V)
3-phase, 200~230V(±10%)
Maximum Output
Frequency (Hz)
400Hz
Protective Structure IP20
Cooling Method Self cooling Forced cooling Self cooling Forced cooling
Control Characteristic Control System Space vector PWM control
Torque Control V/F control, sensorless vector control     
Output Frequency Range 0.01~400Hz
Frequency Setting
Resolution
Analog Max. setting frequency/500 (DC 5V input),
Max. setting frequency/1000 (DC 10V,4~20mA input)
Digital 0.01Hz (100Hz less), 0.1Hz (100Hz or more)   
Frequency Precision Analog Within 0.1% of output frequency
Digital Within 0.01% of maximum output frequency   
Voltage/Frequency Characteristic Any base frequency setting possible between 0 Hz and 400 Hz, constant torque or reduced torque pattern selection possible
Overload Rating  150% of rated current for 60 sec.
Starting Torque More than 200% (at 0.5Hz)
Torque Boost Manual torque boost can be set between 0~50%
Acceleration/Deceleration
Time Setting
0.1~3000 sec. setting possible
Acceleration/Deceleration Pattern Linear, S-curve, U-curve selection possible
Braking Torque Regenerative 150%(5 sec.)
DC Braking Operating frequency(0~120Hz), operating time(0~10 sec.), operating voltage(0~30%) variable
External DC braking setting possible
Current stall Prevention
Operation Level
Operation current level setting possible(0~200% variable), enable/disable selection
Voltage Stall Prevention
Operation Level
Operation level constant, enable/disable selection
Input Signals Frequency
Setting
Analog 0 to 5V DC, 0 to 10V DC, 4 to 20mA,
External variable resistor(1~2㏀, 1W), main unit volume resistor input from control panel
Digital Control panel
Starting Signal Individual selection of forward or reverse run
Abnormality Reset Used to reset protective state provided when protective function is activated
Multispeed Selection Up to 16 set speeds (each speed can be set between 0Hz and 400Hz), speed can be changed during operation
2nd Function
Selection
Acceleration/deceleration time, base frequency, maximum frequency, multistage frequency, torque boost, electronic thermal, control method, motor parameter
Output Stop Instant cutoff of inverter output (frequency/voltage)
Current Input
Selection
Input selection of frequency setting current signal
Self-protection Function at Starting Self-protection selection of start signal
External Trip
Contact Input
Contact input for when stopping the inverter with external terminal
External Thermal
Input
Thermal contact input for when stopping inverter with externally mounted thermal relay
Operation Mode
Selection
Control panel or external operation transition selection possible
Voltage/Frequency Characteristic V/F control or sensorless vector control method selection possible
Operation Functions Multispeed operation, operation mode selection, DC braking, upper/lower frequency setting, frequency jump operation, PID control, AVR, 2-stage accel./decel., instantaneous power failure restart operation, electronic thermal, software lock, carrier frequency adjustment, auto tuning function, forward/reverse run prevention, RS485 link operation
Output
Signals
Operation Status Inverter running, frequency reached, frequency detection, overload warning fault
For Meter Output frequency, output current, output voltage
Display Function Displayed on
Control Panel
Operation Status Output frequency, output current, output voltage, operation direction, PID feedback, terminal input, terminal output
Error Details Fault list, fault history
Protective and
Warning Functions
Overcurrent cutoff, regenerative overvoltage cutoff, undervoltage, output short circuit, temperature abnormality, overload cutoff (electronic thermal), ground fault protection
Environment Ambient Temperature /Storage Temperature  -10℃~50℃ (no freezing) / -20℃~60℃
Ambient Humidity /
Installation Area
90%RH or less(no condensing) / Indoors (no corrosive gases, no flammable gases, no oil mist and no dust)
Altitude and Vibration  Maximum 1000m or less above sea level, 5.9㎨ or less
Operator Standard operator built-in control board, optional remote operator
Misc. International Directive Compliance UL/CE directive compliance (to be scheduled)

400V Class

Item(N100) 004HF 007HF 015HF 022HF 037HF
Output Applicable Motor
Capacity (kW)
0.4 0.75 1.5 2.2 3.7
Rated Output Capacity (kVA) 1.8 3.4 4.8 7.2 9.2
Rated Output Current (A) 1.1 1.9 3 4.2 6.1
Rated Output Voltage (V) 3-phase, 380~460V(±10%)
Maximum Output Frequency (Hz) 400Hz
Protective Structure IP20
Cooling Method Self cooling Forced cooling
Control Characteristic Control System Space vector PWM control
Torque Control V/F control, sensorless vector control
Output Frequency Range 0.01~400Hz
Frequency Setting Resolution Analog Max. setting frequency/500 (DC 5V input),
Max. setting frequency/1000 (DC 10V,4~20mA input)
Digital 0.01Hz (100Hz less), 0.1Hz (100Hz or more)
Frequency Precision Analog Within 0.1% of output frequency
Digital Within 0.01% of maximum output frequency
Voltage/Frequency Characteristic Any base frequency setting possible between 0 Hz and 400 Hz, constant torque or reduced torque pattern selection possible
Overload Rating 150% or rated current for 60 sec.
Starting Torque More than 200% (at 0.5Hz)
Torque Boost Manual torque boost can be set between 0~50%
Acceleration/Deceleration Time Setting 0.1~3000 sec. Setting possible
Accleration/Deceleration Pattern Linear, S-curve, U-curve selection possible
Braking Torque Regenerative 150% (5 sec.)
DC Braking Operating frequency(0~120Hz), Operating time(0~10 sec.), operating voltage(0~30%) variable
Current Stall Prevention Operation Level Operation current level setting possible(0~200% variable), enable/disable selection
Voltage Stall Prevention Operation Level Operation level constant, enable/disable selection
Input Signal Frequency Setting Analog 0 to 5VDC, 0 to 10VDC, 4 to 20mA, External variable resistor(1~2㏀, 1W), main unit volume resistor input from control panel
Digital Control panel
Starting Signal Individual selection of forward or reverse run
Abnormality Reset Used to reset protective state provided when protective function is activated
Multispeed Selection Up to 16 set speeds (each speed can be set between 0Hz and 400Hz), speed can be changed during operation
2nd Function Selection Acceleration/deceleration time, base frequency, maximum frequency, multistage frequency, torque boost, electronic thermal, control method, motor parameter
Output Stop Instant cutoff of inverter output (frequency/voltage)
Current Input Selection Input selection of frequency setting current signal
Self-protection Functional at Starting Self-protection selection of start signal
External Trip Contact Input Contact input for when stopping the inverter with external terminal
Eternal Thermal Input Thermal contact input for when stopping inverter with externally mounted thermal relay
Operation Mode Selection Control panel or external operation transition selection possible
Voltage/Frequency Characteristic V/F control or sensorless vector control method selection possible
Operation Functions Multispeed operation, operation mode selection, DC braking, upper/lower frequency setting, frequency jump operation, PID control
AVR, 2-stage accel./decel., instantaneous power failure restart operation, electronic thermal, software lock, carrier frequency adjustment, auto tuning function,
forward/reverse run prevention, RS485 link operation
Output Signals Operation Status Inverter running, frequency reached, frequency detection, overload warning fault
For Meter Output frequency, output current, output voltage
Display Function Displayed on Control Panel Operation Status Output frequency, output current, output voltage, operation direction, PID feedback, terminal input, terminal output, transition frequency monitor, power consumption, operating time accumulation
Error Details Fault list, fault history
Protective and Warning Functions Overcurrent cutoff, regenerative overvoltage cutoff, undervoltage, output short circuit, temperature abnormality, overload cutoff (electronic thermal), ground fault protection
External trip, communication error, USP error, EEPROM error
Environment Ambient Temperature / Storage Temperature -10℃~50℃ (no freezing) / -20℃~60℃
Ambient Humidity / Installation Area 90%RH or less(no condensing) / Indoors (no corrosive gases, no flammable gases, no oil mist and no dust)
Altitude and Vibration Maximum 1000m or less above sea level, 5.9㎨ or less
Operator Standard operator built-in control board, optional remote operator
Misc. International Directive Compliance UL/CE directive compliance (to be scheduled)